HW Series

HW series is a special UPS that can withstand the harsh outdoor environment.It has the globally newest period control component and more advanced software combined in a full intelligent digital product.

The HW series product uses the six generators low-loss large power IGBT and static switch to power the component. Fully adaptable digital control technology with an available online programmable high-speed microprocessor(MCU) which performance perfectly with digital electric technology.

Scroll down to also see HW-L series UPS.

ModelHW – 1KHW – 2KHW – 3K
Capacity1kVA2kVA3kVA
Power Watt0.8kW1.6kW2.4kW
Working PrincipleLow Frequency, Transformer Based
True On Line-Double Conversion
Low Frequency, Transformer Based
True On Line-Double Conversion
Low Frequency, Transformer Based
True On Line-Double Conversion
Input (Rectifier)
Phase1 phase1 phase1 phase
Voltage Range220VAC (230VAC or 240VAC) ±25%220VAC (230VAC or 240VAC) ±25%220VAC (230VAC or 240VAC) ±25%
Frequency Range50Hz ±10% / 60Hz ±10% (Selectable)50Hz ±10% / 60Hz ±10% (Selectable)50Hz ±10% / 60Hz ±10% (Selectable)
Output RippleLess than 2%Less than 2%Less than 2%
Soft Start0 up to 100% 5sec0 up to 100% 5sec0 up to 100% 5sec
Charging
Charging ModeConstant current, then constant voltage and charge with temperature compensationConstant current, then constant voltage and charge with temperature compensationConstant current, then constant voltage and charge with temperature compensation
Float Charging Voltage55VDC55VDC55VDC
Equalized Charging Voltage56.8VDC56.8VDC56.8VDC
Temp. Compensated Voltage-3mV / ℃ / cell-3mV / ℃ / cell-3mV / ℃ / cell
Charging Current5 – 10A5 – 10A5 – 10A
Battery
TypeVRLA / AGM / Gel
Optional Lithium Battery
VRLA / AGM / Gel
Optional Lithium Battery
VRLA / AGM / Gel
Optional Lithium Battery
Battery Capacity7 up to 200AH settable
(Configuration Battery Capacity according to Back-up Time)
7 up to 200AH settable
(Configuration Battery Capacity according to Back-up Time)
7 up to 200AH settable
(Configuration Battery Capacity according to Back-up Time)
Quantity4 units 12V or
24 units 2V batteries
(Battery Voltage 48VDC)
4 units 12V or
24 units 2V batteries
(Battery Voltage 48VDC)
4 units 12V or
24 units 2V batteries
(Battery Voltage 48VDC)
Temperature20ºC up to 25ºC (For Maximum Efficiency)20ºC up to 25ºC (For Maximum Efficiency)20ºC up to 25ºC (For Maximum Efficiency)
Output (Inverter)
Phase1 Phase1 Phase1 Phase
Nominal Voltage220VAC (230VAC or 240VAC)220VAC (230VAC or 240VAC)220VAC (230VAC or 240VAC)
Output Voltage Regulated Accuracy± 1%( Stable load)
± 3% (Fluctuate load)
± 1%( Stable load)
± 3% (Fluctuate load)
± 1%( Stable load)
± 3% (Fluctuate load)
Output Frequency Range50Hz 60Hz less than ±0.5% (Asynchronous )50Hz 60Hz less than ±0.5% (Asynchronous )50Hz 60Hz less than ±0.5% (Asynchronous )
Crest FactorGreater than 3:1Greater than 3:1Greater than 3:1
Total Harmonic Distortion (THD)Pure Sine Wave
Linear Load less than 3%
Non-Linear Load less than 5%
50Hz, 60Hz less than ±0. 5%50Hz, 60Hz less than ±0. 5%
Dynamic CharacteristicsInstant voltage less than ±5% (from 0 to 100%)
Instant recover time less than 10ms
Instant voltage less than ±5% (from 0 to 100%)
Instant recover time less than 10ms
Instant voltage less than ±5% (from 0 to 100%)
Instant recover time less than 10ms
Overload CapacityAt 115% load, normal work
At 125% load 10 min
At 150% load 1min
At 115% load, normal work
At 125% load 10 min
At 150% load 1min
At 115% load, normal work
At 125% load 10 min
At 150% load 1min
Inverter EfficiencyGreater than 93% (full load)Greater than 93% (full load)Greater than 93% (full load)
Bypass
Phase1 Phase + P + N1 Phase + P + N1 Phase + P + N
Nominal Voltage220VAC (230VAC or 240VAC)220VAC (230VAC or 240VAC)220VAC (230VAC or 240VAC)
Transfer Time0ms (adopt static switch)0ms (adopt static switch)0ms (adopt static switch)
Protection
Input ProtectionInput voltage, frequency over limited protectionInput voltage, frequency over limited protectionInput voltage, frequency over limited protection
Output ProtectionOver current, short circuit, over voltage, low voltageOver current, short circuit, over voltage, low voltageOver current, short circuit, over voltage, low voltage
Battery ProtectionOver charge, over-discharge protectionOver charge, over-discharge protectionOver charge, over-discharge protection
Temperature ProtectionEnvironment over temperature protection
Inverter over temperature protection
Environment over temperature protection
Inverter over temperature protection
Environment over temperature protection
Inverter over temperature protection
Hardware Fault ProtectionAssistant power abnormal, breaker cut off, breaker overload, power devices over current/over voltage etc. protectionAssistant power abnormal, breaker cut off, breaker overload, power devices over current/over voltage etc. protectionAssistant power abnormal, breaker cut off, breaker overload, power devices over current/over voltage etc. protection
System Parameters
Working EnvironmentTemp: -25 up to 55ºC
Relative humidity: 30% up to 90%
Altitude less than 2000m (power reduce 1% every 100M raised, 4000M utmost)
Temp: -25 up to 55ºC
Relative humidity: 30% up to 90%
Altitude less than 2000m (power reduce 1% every 100M raised, 4000M utmost)
Temp: -25 up to 55ºC
Relative humidity: 30% up to 90%
Altitude less than 2000m (power reduce 1% every 100M raised, 4000M utmost)
Cooling MethodCompulsive ventilationCompulsive ventilationCompulsive ventilation
Communication InterfaceRS232 / RS485
Optional dry contact, SNMP card
(for remote control via internet)
RS232 / RS485
Optional dry contact, SNMP card
(for remote control via internet)
RS232 / RS485
Optional dry contact, SNMP card
(for remote control via internet)
Protection LevelIP43IP43IP43
Safety PerformanceVin-n Vout-n 2000VAC,
Creepage less than 10mA
Insulating resistance greater than 2MΩ (500VDC)
Vin-n Vout-n 2000VAC,
Creepage less than 10mA
Insulating resistance greater than 2MΩ (500VDC)
Vin-n Vout-n 2000VAC,
Creepage less than 10mA
Insulating resistance greater than 2MΩ (500VDC)
Anti-Surge Capacity10/700μS, 5KV;
8/20μS, 20KA
10/700μS, 5KV;
8/20μS, 20KA
10/700μS, 5KV;
8/20μS, 20KA
Noise45 up to 50dB45 up to 50dB45 up to 50dB

NOTE: Baykee Australasia reserves the right to change or modify product design, construction, specifications or materials without prior notice and without incurring any obligation to make such changes and modifications on Baykee Australasia products previously or subsequently sold.