HD Series 1/1 Phase UPS

Capacity 1000VA – 5000VA.

HD series UPS is a smart multi-functional line interactive UPS, consisting of inverters, automatic voltage regulator, a conversion circuit, main control circuit and display alarm circuits, etc.

Designed to protect your computer and other important electronic facilities from power failure, brownouts, sags, and surges. The UPS can filter out the small voltage fluctuations. When meeting big voltage disturbance the UPS can disconnect AC input by the internal circuit, in order to avoid an influence of your facility.

The UPS can offer uninterruptible power supply thru lead acid battery or lithium battery until the utility power recover. When the utility power is normal, the UPS has voltage regulation function by the internal automatic voltage regulator and simultaneously charge the battery. During downtime the UPS can change the battery energy into pure sine wave AC power, thereby making the load work.

Capacity1000VA1500VA2000VA3000VA4000VA5000VA
Power Watt800W1200W1600W2400W3200W4000W
Work ModeLow Frequency Line InteractiveLow Frequency Line InteractiveLow Frequency Line InteractiveLow Frequency Line InteractiveLow Frequency Line InteractiveLow Frequency Line Interactive
Voltage Regulation
Function
Adopt relay smart multi-gear adjusting voltageAdopt relay smart multi-gear adjusting voltageAdopt relay smart multi-gear adjusting voltageAdopt relay smart multi-gear adjusting voltageAdopt relay smart multi-gear adjusting voltageAdopt relay smart multi-gear adjusting voltage
Output Voltage Regulation Precision±5%±5%±5%±5%±5%±5%
Input
Phase1 Phase (P + N + PE)1 Phase (P + N + PE)1 Phase (P + N + PE)1 Phase (P + N + PE)1 Phase (P + N + PE)1 Phase (P + N + PE)
Rated Voltage100 / 110 / 120VAC or
220 / 230 / 240VAC
(According to Users’ Voltage Standard)
100 / 110 / 120VAC or
220 / 230 / 240VAC
(According to Users’ Voltage Standard)
100 / 110 / 120VAC or
220 / 230 / 240VAC
(According to Users’ Voltage Standard)
100 / 110 / 120VAC or
220 / 230 / 240VAC
(According to Users’ Voltage Standard)
100 / 110 / 120VAC or
220 / 230 / 240VAC
(According to Users’ Voltage Standard)
100 / 110 / 120VAC or
220 / 230 / 240VAC
(According to Users’ Voltage Standard)
Voltage Range±25%±25%±25%±25%±25%±25%
Rated Frequency50 / 60Hz (Self-adaptive)50 / 60Hz (Self-adaptive)50 / 60Hz (Self-adaptive)0.99550 / 60Hz (Self-adaptive)50 / 60Hz (Self-adaptive)50 / 60Hz (Self-adaptive)
Frequency Range±5%±5%±5%±5%±5%±5%
Battery
Voltage24VDC24VDC48VDC48VDC48VDC48VDC
Charging ModeThree-stage Intelligent Battery ChargingThree-stage Intelligent Battery ChargingThree-stage Intelligent Battery ChargingThree-stage Intelligent Battery ChargingThree-stage Intelligent Battery ChargingThree-stage Intelligent Battery Charging
Float Charging Voltage27VDC27VDC27VDC27VDC27VDC27VDC
Equalized Charging Voltage28.2VDC28.2VDC56.4VDC56.4VDC56.4VDC56.4VDC
Temperature Compensate
Voltage
3mV / ℃ / cell3mV / ℃ / cell3mV / ℃ / cell3mV / ℃ / cell3mV / ℃ / cell3mV / ℃ / cell
Charging PowerRated Capacity * 20%Rated Capacity * 20%Rated Capacity * 20%Rated Capacity * 20%Rated Capacity * 20%Rated Capacity * 20%
Output
PhaseSingle Phase (P + N + PE)Single Phase (P + N + PE)Single Phase (P + N + PE)Single Phase (P + N + PE)Single Phase (P + N + PE)Single Phase (P + N + PE)
Nominal VoltageEqual to Input Rated VoltageEqual to Input Rated VoltageEqual to Input Rated VoltageEqual to Input Rated VoltageEqual to Input Rated VoltageEqual to Input Rated Voltage
Inverter Output Voltage100 / 110 / 115 / 127V;
220 / 230 / 240V
(According to users’ Voltage standard)
100 / 110 / 115 / 127V;
220 / 230 / 240V
(According to users’ Voltage standard)
100 / 110 / 115 / 127V;
220 / 230 / 240V
(According to users’ Voltage standard)
100 / 110 / 115 / 127V;
220 / 230 / 240V
(According to users’ Voltage standard)
100 / 110 / 115 / 127V;
220 / 230 / 240V
(According to users’ Voltage standard)
100 / 110 / 115 / 127V;
220 / 230 / 240V
(According to users’ Voltage standard)
Inverter Output Degree of Stability±1% (Steady load)
±3% (Fluctuation of load)
±1% (Steady load)
±3% (Fluctuation of load)
±1% (Steady load)
±3% (Fluctuation of load)
±1% (Steady load)
±3% (Fluctuation of load)
±1% (Steady load)
±3% (Fluctuation of load)
±1% (Steady load)
±3% (Fluctuation of load)
Inverter Frequency Degree of Stability50Hz, 60Hz less than ±0.5%50Hz, 60Hz less than ±0.5%50Hz, 60Hz less than ±0.5%50Hz, 60Hz less than ±0.5%50Hz, 60Hz less than ±0.5%50Hz, 60Hz less than ±0.5%
Crest FactorGreater than 3:1Greater than 3:1Greater than 3:1Greater than 3:1Greater than 3:1Greater than 3:1
Inverter Output THDPure sine wave
Linear load less than 3%
Non-linear load less than 5%
Pure sine wave
Linear load less than 3%
Non-linear load less than 5%
Pure sine wave
Linear load less than 3%
Non-linear load less than 5%
Pure sine wave
Linear load less than 3%
Non-linear load less than 5%
Pure sine wave
Linear load less than 3%
Non-linear load less than 5%
Pure sine wave
Linear load less than 3%
Non-linear load less than 5%
Transfer TimeLess than 5msLess than 5msLess than 5msLess than 5msLess than 5msLess than 5ms
Protection
Input ProtectionVoltage, Frequency Ultra-Limit ProtectionVoltage, Frequency Ultra-Limit ProtectionVoltage, Frequency Ultra-Limit ProtectionVoltage, Frequency Ultra-Limit ProtectionVoltage, Frequency Ultra-Limit ProtectionVoltage, Frequency Ultra-Limit Protection
Output ProtectionOver Current, Short Circuit ProtectionOver Current, Short Circuit ProtectionOver Current, Short Circuit ProtectionOver Current, Short Circuit ProtectionOver Current, Short Circuit ProtectionOver Current, Short Circuit Protection
Battery ProtectionOvercharging, Short Circuit ProtectionOvercharging, Short Circuit ProtectionOvercharging, Short Circuit ProtectionOvercharging, Short Circuit ProtectionOvercharging, Short Circuit ProtectionOvercharging, Short Circuit Protection
Temperature ProtectionOver-Temperature ProtectionOver-Temperature ProtectionOver-Temperature ProtectionOver-Temperature ProtectionOver-Temperature ProtectionOver-Temperature Protection
Hardware Fault ProtectionFuse Over Current Protection, Surge Voltage ProtectionFuse Over Current Protection, Surge Voltage ProtectionFuse Over Current Protection, Surge Voltage ProtectionFuse Over Current Protection, Surge Voltage ProtectionFuse Over Current Protection, Surge Voltage ProtectionFuse Over Current Protection, Surge Voltage Protection
Alarm FunctionAudio AlarmAudio AlarmAudio AlarmAudio AlarmAudio AlarmAudio Alarm
Overload LevelOverload Level
105 up to 125%Greater than 10 mins
125 up to 150%Greater than 1 mins
Greater than 150%Immediate Protection
System Parameter
Work TemperatureTemperature: 0 up to 40℃
Relative humidity: 30% up to 90%
Altitude less than 2000m
(Power reduce 1% every 100M raised, 4000M utmost)
Temperature: 0 up to 40℃
Relative humidity: 30% up to 90%
Altitude less than 2000m
(Power reduce 1% every 100M raised, 4000M utmost)
Temperature: 0 up to 40℃
Relative humidity: 30% up to 90%
Altitude less than 2000m
(Power reduce 1% every 100M raised, 4000M utmost)
Temperature: 0 up to 40℃
Relative humidity: 30% up to 90%
Altitude less than 2000m
(Power reduce 1% every 100M raised, 4000M utmost)
Temperature: 0 up to 40℃
Relative humidity: 30% up to 90%
Altitude less than 2000m
(Power reduce 1% every 100M raised, 4000M utmost)
Temperature: 0 up to 40℃
Relative humidity: 30% up to 90%
Altitude less than 2000m
(Power reduce 1% every 100M raised, 4000M utmost)
Cooling MethodForced ventilationForced ventilationForced ventilationForced ventilationForced ventilationForced ventilation
Communication InterfaceRS232
(Optional USB, SNMP card)
RS232
(Optional USB, SNMP card)
RS232
(Optional USB, SNMP card)
RS232
(Optional USB, SNMP card)
RS232
(Optional USB, SNMP card)
RS232
(Optional USB, SNMP card)
Protection LevelIP30IP30IP30IP30IP30IP30
Safety PerformanceI/O on ground resistance (3000VAC)
Stray current less than 3.5mA
Insulation resistance exceeding 2MΩ (500VDC)
I/O on ground resistance (3000VAC)
Stray current less than 3.5mA
Insulation resistance exceeding 2MΩ (500VDC)
I/O on ground resistance (3000VAC)
Stray current less than 3.5mA
Insulation resistance exceeding 2MΩ (500VDC)
I/O on ground resistance (3000VAC)
Stray current less than 3.5mA
Insulation resistance exceeding 2MΩ (500VDC)
I/O on ground resistance (3000VAC)
Stray current less than 3.5mA
Insulation resistance exceeding 2MΩ (500VDC)
I/O on ground resistance (3000VAC)
Stray current less than 3.5mA
Insulation resistance exceeding 2MΩ (500VDC)
Tower Type Dimension
( W*H*D ) mm
145 * 225 *360195 * 345 * 460195 * 345 * 460195 * 345 * 460195 * 222 * 450195 * 222 * 450
Rack-Mounted Type
( W*H*D ) mm
482 * 88 * 300482 * 133 * 400482 * 133 * 400482 * 133 * 400482 * 222 * 450482 * 222 * 450

NOTE: Subject to changes without further notice!