CHP3000 Series 3/3 Phase UPS

Cabinet power range 300 kVA and 400 kVA.

CHP3000 series UPS uses a high-speed microprocessor (MCU) and a programmable logic device (CPLD) program which is controlled by software.

It brings in the sixth generation low-exhaust and big-power IGBT and static switch as power components. It enters into deducing digital ages of classic legend, bring up with the big capacity, high reliability, stability of function to reside global top-grade level. This series product combines the world’s newest control spare parts and the most advanced software.

CHP3000 series UPS entirely breaks through the technical bottleneck in traditional simulation age, it adopts the digital control technology and high-precision SMD technology to assure ultra-high system stability and to fully acclimate various grid environment.

Single-machine capacity is ranging from 10kVA to 600kVA, which is widely used in telecom, bank, security, transporting, utility, manufacture, industry, government etc.

ModelCHP3300KCHP3400K
Capacity300kVA400kVA
Power Watt240kW320kW
Working PrincipalLow-Frequency Transformer Based True On Line-Double ConversionLow-Frequency Transformer Based True On Line-Double Conversion
RECTIFIER (INPUT)
PhaseThree PhaseThree Phase
Input Power FactorStandard ≧0.9 (6 Pulse rectifier + Filter)
Optional ≧0.96 (12 Pulse rectifier + Filter)
Standard ≧0.9 (6 Pulse rectifier + Filter)
Optional ≧0.96 (12 Pulse rectifier + Filter)
Input Voltage Range220 / 380VAC (230V / 400VAC or 240V / 415VAC) ±25% 3P+N+PE

110V / 208VAC (120V / 220VAC or 277V / 480VAC) optional

220 / 380VAC (230V / 400VAC or 240V / 415VAC) ±25% 3P+N+PE

110V / 208VAC (120V / 220VAC or 277V / 480VAC) optional

Input Frequency Range50Hz ±10%
60Hz ±10% (Selectable)
50Hz ±10%
60Hz ±10% (Selectable)
Total Harmonic Distortion

(THDi)

6 Pulse Rectifier less than 30%
Optional 12 Pulse Rectifier & Filter less than 5%
6 Pulse Rectifier less than 30%
Optional 12 Pulse Rectifier & Filter less than 5%
Output Ripple Less than 2% Less than 2%
Soft Start0 up to 100% 5sec0 up to 100% 5sec
CHARGING
Charging ModeConstant current, then constant voltage. Charge with temperature compensation, automatic switch between equalized charging and float charging.Constant current, then constant voltage. Charge with temperature compensation, automatic switch between equalized charging and float charging.
Float Charging Voltage432VDC432VDC
Equalized Charging Voltage464VDC464VDC
Temp. Compensated

Voltage

-3mV / ℃ / Cell-3mV / ℃ / Cell
Charging Current0.1C (Automatic adjust according to battery capacity)0.1C (Automatic adjust according to battery capacity)
BATTERY
TypeVRLA / AGM / Gel,
optional Lithium Battery
VRLA / AGM / Gel,
optional Lithium Battery
Battery Capacity7 up to 999AH settable (Configure Battery Capacity according to Back-up Time)7 up to 999AH settable (Configure Battery Capacity according to Back-up Time)
Quantity32 units 12V or 192 units 2V batteries (Nominal Voltage 384VDC)32 units 12V or 192 units 2V batteries (Nominal Voltage 384VDC)
Temperature20ºC up to 25ºC (For Maximum Efficiency)20ºC up to 25ºC (For Maximum Efficiency)
INVERTER (OUTPUT)
PhaseThree PhaseThree Phase
Rated VoltageRated Capacity * 0.9Rated Capacity * 0.9
Nominal Voltage220 / 380VAC (230V / 400VAC or 240V / 415VAC), 3P+N

110V / 208VAC (120V / 220VAC or 277V / 480VAC) optional

220 / 380VAC (230V / 400VAC or 240V / 415VAC), 3P+N

110V / 208VAC (120V / 220VAC or 277V / 480VAC) optional

Output Voltage Regulated Accuracy±1% (Stable load)
±3% (Fluctuant load)
±1% (Stable load)
±3% (Fluctuant load)
Output Frequency Range50Hz – 60Hz less than ±0.5% (Asynchronous)50Hz – 60Hz less than ±0.5% (Asynchronous)
Crest FactorGreater than 3:1Greater than 3:1
Output Total Harmonic

Distortion (THD)

Pure Sine Wave
Linear Load less than 3%
Non-Linear Load less than 5%
Pure Sine Wave
Linear Load less than 3%
Non-Linear Load less than 5%
Dynamic CharacteristicsInstant voltage less than ±5% (0 – 100%)
Instant recover time less than 10ms
Instant voltage less than ±5% (0 – 100%)
Instant recover time less than 10ms
Unbalanced Load VoltageLess than ±5%Less than ±5%
Overload CapacityAt 115% load, normal work
At 125% load 10min
At 150% load 1min
At 200% load 1sec
At 115% load, normal work
At 125% load 10min
At 150% load 1min
At 200% load 1sec
Inverter EfficiencyGreater than 95% (full load)Greater than 95% (full load)
BYPASS
PhaseThree Phase +NThree Phase +N
Input Nominal Voltage220 / 380VAC (230V / 400VAC or 240V / 415VAC)

110V / 208VAC (120V / 220VAC or 277V / 480VAC) optional

220 / 380VAC (230V / 400VAC or 240V / 415VAC)

110V / 208VAC (120V / 220VAC or 277V / 480VAC) optional

Output Nominal Voltage220 / 380VAC (230V / 400VAC or 240V / 415VAC)

110V / 208VAC (120V / 220VAC or 277V / 480VAC) optional

220 / 380VAC (230V / 400VAC or 240V / 415VAC)

110V / 208VAC (120V / 220VAC or 277V / 480VAC) optional

Transfer Time0ms (adopt static switch)0ms (adopt static switch)
PROTECTION FUNCTION
Input ProtectionInput voltage, frequency over limited protection, phase fault, phase lackInput voltage, frequency over limited protection, phase fault, phase lack
Output ProtectionOver current, short circuit, over voltage, low voltageOver current, short circuit, over voltage, low voltage
Battery ProtectionOver charge, over-discharge protectionOver charge, over-discharge protection
Temperature ProtectionEnvironment over temperature protection, inverter over temperature protectionEnvironment over temperature protection, inverter over temperature protection
Hardware Fault ProtectionAssistant power abnormal, breaker cut off, breaker overload, power devices over current/over voltage etc. protectionAssistant power abnormal, breaker cut off, breaker overload, power devices over current/over voltage etc. protection
GENERAL SYSTEM PARAMETERS
Working EnvironmentTemp: -10 up to 40ºC,
Relative humidity: 30% up to 90%
Altitude less than 2000m (1% decrease against 100m rise, Max. altitude 4000m)
Temp: -10 up to 40ºC,
Relative humidity: 30% up to 90%
Altitude less than 2000m (1% decrease against 100m rise, Max. altitude 4000m)
Cooling MethodCOMPULSIVE VENTILATIONCOMPULSIVE VENTILATION
Communication InterfaceRS232 / RS485, optional dry contact, SNMP card (for remote control via internet)RS232 / RS485, optional dry contact, SNMP card (for remote control via internet)
Parallel OperationTandem hot backup or parallel connectionTandem hot backup or parallel connection
Auto-surge Capacity10 / 700μS
5KV; 8 / 20μS
20KA
10 / 700μS
5KV; 8 / 20μS
20KA
Protection LevelIP30IP30
Safety PerformanceVin-n Vout-n 3000Vac, creepage less than 3.5mA, insulating resistance greater than 2MΩ (500VDC)Vin-n Vout-n 3000Vac, creepage less than 3.5mA, insulating resistance greater than 2MΩ (500VDC)
Noise (dB)65 up to 7065 up to 70
Dimension (W*D*H) mm2000 * 900 * 20002000 * 900 * 2000
Weight (Kg)28103060

NOTE: Subject to changes without further notice!